Firmware hub (FWH) interface Configuration Registers
M50FW040
6.7
Device Code Register
Reading the Device Code Register returns the device code for the memory, 2Ch. This
register is read-only and writing to it has no effect.
Table 9. Firmware hub Configuration Register map
Mnemonic
Register Name
Memory
Address
Default
Value
Access
T_BLOCK_LK Top Block Lock Register (Block 7)
FBF0002h 01h
T_MINUS01_LK Top Block [-1] Lock Register (Block 6)
FBE0002h 01h
T_MINUS02_LK Top Block [-2] Lock Register (Block 5)
FBD0002h 01h
T_MINUS03_LK Top Block [-3] Lock Register (Block 4)
FBC0002h 01h
T_MINUS04_LK Top Block [-4] Lock Register (Block 3)
FBB0002h 01h
T_MINUS05_LK Top Block [-5] Lock Register (Block 2)
FBA0002h 01h
T_MINUS06_LK Top Block [-6] Lock Register (Block 1)
FB90002h 01h
T_MINUS07_LK Top Block [-7] Lock Register (Block 0)
FB80002h 01h
FGPI_REG
Firmware Hub (FWH) General Purpose Input
Register
FBC0100h
N/A
MANUF_REG Manufacturer Code Register
FBC0000h 20h
DEV_REG Device Code Register
FBC0001h 2Ch
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
Table 10. Lock Register bit definitions(1)
Bit Bit name Value
Function
7-3
2
Read-
Lock
1
Lock-
Down
0
Write-
Lock
Reserved
‘1’ Bus Read operations in this Block always return 00h.
‘0’
Bus read operations in this Block return the Memory Array contents.
(Default value).
Changes to the Read-Lock bit and the Write-Lock bit cannot be
‘1’
performed. Once a ‘1’ is written to the Lock-Down bit it cannot be cleared
to ‘0’; the bit is always reset to ‘0’ following a Reset (using RP or INIT) or
after power-up.
‘0’
Read-Lock and Write-Lock can be changed by writing new values to
them. (Default value).
‘1’
Program and Erase operations in this Block will set an error in the Status
Register. The memory contents will not be changed. (Default value).
‘0’
Program and Erase operations in this Block are executed and will modify
the Block contents.
1. Applies to Top Block Lock Register (T_BLOCK_LK) and Top Block [-1] Lock Register (T_MINUS01_LK) to
Top Block [-7] Lock Register (T_MINUS07_LK).
32/53