DC and AC parameters
9
DC and AC parameters
M50FW040
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics Tables that
follow, are derived from tests performed under the Measurement Conditions summarized in
Table 14, Table 15 and Table 16. Designers should check that the operating conditions in
their circuit match the operating conditions when relying on the quoted parameters.
Table 14. Operating conditions
Symbol
Parameter
Min
Max
TA
Ambient Operating Temperature (Device Grade 5)
VCC
Supply Voltage
–20
85
3
3.6
Table 15. FWH interface AC measurement conditions
Parameter
Value
Load Capacitance (CL)
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
10
≤1.4
0.2 VCC and 0.6 VCC
0.4 VCC
Table 16. A/A Mux interface AC measurement conditions
Parameter
Value
Load Capacitance (CL)
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
30
≤10
0 to 3
1.5
Unit
°C
V
Unit
pF
ns
V
V
Unit
pF
ns
V
V
Figure 8. FWH interface AC testing input output waveforms
0.6 VCC
0.4 VCC
0.2 VCC
Input and Output AC Testing Waveform
36/53
IO < ILO
IO > ILO
IO < ILO
Output AC Tri-state Testing Waveform
AI03404