M50FLW040A, M50FLW040B
DC AND AC PARAMETERS
This section summarizes the operating measure-
ment conditions, and the DC and AC characteris-
tics of the device. The parameters in the DC and
AC characteristics Tables that follow, are derived
from tests performed under the Measurement
Conditions summarized in Table 20., Table 21.
and Table 22.. Designers should check that the
operating conditions in their circuit match the oper-
ating conditions when relying on the quoted pa-
rameters.
Table 20. Operating Conditions
Symbol
Parameter
Min.
Max.
Unit
VCC
Supply Voltage
3.0
3.6
V
Ambient Operating Temperature (Device Grade 5)
–20
85
°C
TA
Ambient Operating Temperature (Device Grade 1)
0
70
°C
Table 21. FWH/LPC Interface AC Measurement Conditions
Parameter
Load Capacitance (CL)
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
Value
10
≤ 1.4
0.2 VCC and 0.6 VCC
0.4 VCC
Unit
pF
ns
V
V
Table 22. A/A Mux Interface AC Measurement Conditions
Parameter
Load Capacitance (CL)
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
Value
Unit
30
pF
≤ 10
ns
0 to 3
V
1.5
V
Figure 11. FWH/LPC Interface AC Measurement I/O Waveforms
0.6 VCC
0.4 VCC
0.2 VCC
Input and Output AC Testing Waveform
28/52
IO < ILO
IO > ILO
IO < ILO
Output AC Tri-state Testing Waveform
AI03404