Numonyx™ Wireless Flash Memory (W18)
Table 10: Extended Temperature Operation (Sheet 2 of 2)
Symbol
Parameter1
Min
Nom
Max
Unit
Note
Block
Erase
Cycles
Main and Parameter Blocks
Main Blocks
Parameter Blocks
VPP ≤ VCC
VPP = 12 V
VPP = 12 V
100,000
-
-
-
-
-
-
1
1000
Cycles
1
2500
1
Notes:
1.
VPP is normally VPP1. VPP can be connected to 11.4 V–12.6 V for 1000 cycles on main blocks at extended temperatures
and 2500 cycles on parameter blocks at extended temperatures.
2.
Contact your Numonyx field representative for VCC/VCCQ operations down to 1.65 V.