PIC12F/LF1822/16F/LF1823
FIGURE 29-14: USART SYNCHRONOUS TRANSMISSION (MASTER/SLAVE) TIMING
CK
US121
US121
DT
Note:
US120
Refer to Figure 29-5 for load conditions.
US122
TABLE 29-13: USART SYNCHRONOUS TRANSMISSION REQUIREMENTS
Standard Operating Conditions (unless otherwise stated)
Operating Temperature
-40°C TA +125°C
Param.
No.
Symbol
Characteristic
Min. Max.
US120 TCKH2DTV SYNC XMIT (Master and Slave)
3.0-5.5V
—
80
Clock high to data-out valid
1.8-5.5V
—
100
US121 TCKRF
Clock out rise time and fall time
3.0-5.5V
—
45
(Master mode)
1.8-5.5V
—
50
US122 TDTRF
Data-out rise time and fall time
3.0-5.5V
—
45
1.8-5.5V
—
50
Units Conditions
ns
ns
ns
ns
ns
ns
FIGURE 29-15: USART SYNCHRONOUS RECEIVE (MASTER/SLAVE) TIMING
CK
US125
DT
Note: Refer to Figure 29-5 for load conditions.
US126
TABLE 29-14: USART SYNCHRONOUS RECEIVE REQUIREMENTS
Standard Operating Conditions (unless otherwise stated)
Operating Temperature -40°C TA +125°C
Param.
No.
Symbol
Characteristic
Min. Max.
US125 TDTV2CKL SYNC RCV (Master and Slave)
Data-hold before CK (DT hold time)
US126 TCKL2DTL Data-hold after CK (DT hold time)
10
—
15
—
Units
ns
ns
Conditions
DS41413A-page 358
Preliminary
2010 Microchip Technology Inc.