ST92141 - 3-PHASE INDUCTION MOTOR CONTROLLER (IMC)
INDUCTION MOTOR CONTROLLER (Cont’d)
COMPARE PHASE U PRELOAD REGISTER
HIGH (CPUH)
R252 - Read/Write
Register Page: 51
Reset Value: 0000 0000 (00h)
7
0
CPUH CPUH CPUH CPUH CPUH CPUH CPUH CPUH
7
6
5
4
3
2
1
0
Bit 7:0 = CPUH[7:0] Most Significant Byte of
phase U preload value
COMPARE PHASE U PRELOAD REGISTER
LOW (CPUL)
R253 - Read/Write
Register Page: 51
Reset Value: 0000 0000 (00h)
7
0
CPUL7 CPUL6 CPUL5 -
-
-
-
-
Bit 7:5 = CPUL[7:5] Low bits of phase U preload
value.
Bit 4:0 = Reserved.
COMPARE 0 PRELOAD REGISTER
(CP0H)
R254 - Read/Write
Register Page: 51
Reset Value: 0000 0000 (00h)
HIGH
7
0
-----
- CP0H1 CP0H0
Bit 7:2 = Reserved.
Bit 1:0 = CP0H[1:0] Most Significant Bits of Com-
pare 0 preload value.
COMPARE 0 PRELOAD REGISTER
(CP0L)
R255 - Read/Write
Register Page: 51
Reset Value: 0000 0000 (00h)
LOW
7
0
CP0L7 CP0L6 CP0L5 CP0L4 CP0L3 CP0L2 CP0L1 CP0L0
Bit 7:0 = CP0L[7:0] Low byte of Compare 0
preload value.
Note: CP0[9:0] value must be greater than 1.
129/179
9