Si3233
is desired since the regulator output voltage has long settling time constants (on the order of tens of milliseconds)
and cannot change rapidly for TRACK = 1 mode. Therefore, the brief on-hook voltage measurement would yield
approximately the same voltage as the off-hook line voltage and would cause the terminal equipment to incorrectly
sense another off-hook terminal.
Constant I Region
VOC
ILIM
VCM
Constant V Region
RLOOP
VTIP
VBATL
TRACK=1
|VTIP - VRING|
VOC
TRACK=0
VOV
VOV
V
Figure 10. VTIP, VRING, and VBAT in the Forward Active State
VRING
VBAT
Table 24. Associated Relevant DC-DC Converter Registers
Parameter
DC-DC Converter Power-off
Control
DC-DC Converter Calibration
Enable/Status
DC-DC Converter PWM Period
DC-DC Converter Min. Off Time
High Battery VoltageāVBATH
Low Battery VoltageāVBATL
VOV
Range
n/a
Resolution Register Bit
n/a
DCOF
Location
Direct Register 14
n/a
n/a
DCCAL
Direct Register 93
0 to 15.564 us
(0 to 1.892 us) +
4 clock cycles
0 to ā94.5 V
0 to ā94.5 V
0 to ā9 V or
0 to ā13.5 V
61.035 ns
61.035 ns
DCN[7:0]
DCTOF[4:0]
Direct Register 92
Direct Register 93
1.5 V
1.5 V
1.5 V
VBATH[5:0]
VBATL[5:0]
VMIND[3:0]
VOV
Direct Register 74
Direct Register 75
Indirect Register 64
Direct Register 66
Note: The ProSLIC uses registers that are both directly and indirectly mapped. A ādirectā register is one that is mapped
directly. An āindirectā register is one that is accessed using the indirect access registers (direct registers 28 through
31).
Preliminary Rev. 0.5