Si3233
Register 15. Power Down Control 2
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
DACM DACON GMM GMON
Type
R/W
R/W
R/W
R/W
Reset settings = 0000_0000
Bit
Name
Function
7:4
Reserved Read returns zero.
3
DACM
Digital to Analog Converter Manual/Automatic Power Control.
0 = Automatic power control.
1 = Manual power control; DACON controls on/off state.
2
DACON Digital to Analog Converter On/Off Power Control.
When DACM = 1:
0 = Digital to analog converter powered off.
1 = Digital to analog converter powered on.
DACON has no effect when DACM = 0.
1
GMM
Transconductance Amplifier Manual/Automatic Power Control.
0 = Automatic power control.
1 = Manual power control; GMON controls on/off state.
0
GMON
Transconductance Amplifier On/Off Power Control.
When GMM = 1:
0 = Analog to digital converter powered off.
1 = Analog to digital converter powered on.
GMON has no effect when GMM = 0.
46
Preliminary Rev. 0.5