PLEASE NOTE: The SMB118 has entered End-of-Life.
SMB118/218
DC OPERATING CHARACTERISTICS (CONTINUED)
(Over commercial operating conditions, unless otherwise noted. All voltages are relative to GND.)
Symbol
Parameter
Notes
Min
Typ
Max
Battery Charger (Note 3), DOCK_DC=5V
VDockdc
VPRECHG
Input Voltage
Precharge voltage threshold
range
VBATT=3.6V
5.0
Programmable: 100mV steps 2.500
3.200
VPRECHG_ACC
Precharge voltage threshold
accuracy
VBATT rising, VPRECHG= 2.5V
and 3.2V
±20
IPRECHG
Nominal precharge current
range
RCSB=0.1Ω , 15mA steps
25
250
∆IPRECHG
ICHG
∆ICHG
VFLT
∆VFLT
VFLT_HYST
Precharge current tolerance
Nominal Fast charge current
Fast charge current tolerance
Float voltage range
Float voltage tolerance
Float voltage hysteresis
(recharge threshold)
IPRECHG = 100mA
RCSB=0.1Ω , 60mA steps
ICHG = 520mA
20mV steps
VFLT = 4.2V
VBATT falling, VFLT - VFLT_HYST
70
100
485
4.000
-1.2
100
520
±0.5
100
130
1000
565
4.620
+1.2
ITERM
Charge termination current
range
RCSB=0.1Ω, 15mA steps
100
145
∆ITERM
THI
TLO
TTSENSE
Tprecharge
Tcharge
VPDDCTH
Termination current tolerance
Charge cutoff temp (high)
Charge cutoff temp (low)
THERM bias current
Precharge timer duration
Charge timer duration
Programmable DOCK_DC
threshold range
ITERM = 100mA
5oC steps
5oC steps
Adjustable (3 setpoints)
Adjustable (3 setpoints)
Programmable in 200 mV
increments
50
100
170
+30
+65
-20
+15
80
100
130
2621
20972
3.4
4.8
VPDDCTHACC DOCK_DC threshold accuracy VPDDCTH = 4.6V
-4
+4
Unit
V
V
mV
mA
mA
mA
mA
V
%
mV
mA
mA
oC
oC
µA
s
s
V
%
Summit Microelectronics, Inc
2107 3.0 10/15/2008
13