Configuration data
13 Configuration data
STFPC320
To read the configuration data from STFPC320, 0x71 command (Section 7.2: Data setting
command on page 36) is sent from the Host to STFPC320. After this, the STFPC320 will
output a maximum of 14 bytes with the configuration data. The Host can choose to read only
a few bytes by pulsing the SCL line according to the number of bytes to be read.
Up to a maximum of 14-bytes are sent from MSB to LSB as configuration data. The 14-bytes
represent the following configuration information.
Figure 21. Configuration data bytes
Byte 1
Byte 2
MSB
LSB
No. of VFD display digits Clock init display location
b7
b4 b3
b0
MSB
LSB
Guard Timer Value
RC Protocol
b7
b4 b3
b0
Byte 3
MSB
VFD Dimming and (ON/OFF) status
b7
b4 b3
RTC Display format
LSB
b0
Byte 4
Byte 5
Byte 6
Byte 7
MSB
b7
MSB
b7
MSB
b7
MSB
b7
Front Panel Hot Keys (1st Byte)
Front Panel Hot Keys (2nd Byte)
Front Panel Hot Keys (3rd Byte)
RC Device Address 1
LSB
b0
LSB
b0
LSB
b0
LSB
b0
48/78