DC and AC parameters
7
DC and AC parameters
STM1403
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics Tables that
follow, are derived from tests performed under the Measurement Conditions summarized in
Table 5: Operating and AC measurement condition. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Table 5. Operating and AC measurement condition
Parameter
STM1403
Unit
VCC/VBAT supply voltage
Ambient operating temperature (TA)
Input rise and fall times
Input pulse voltages
Input and output timing ref. voltages
2.2 to 3.6
V
–40 to 85
°C
≤5
ns
0.2 to 0.8VCC
V
0.3 to 0.7VCC
V
Figure 24. AC testing input/output waveforms
0.8VCC
0.2VCC
0.7VCC
0.3VCC
AI02568
Figure 25. MR timing waveform
MR
tMLRL
RST
tMLMH
trec
AI09694
Figure 26.
STM1403 switchover diagram, condition A (VBAT < VSW)
VCC = 3.3V
VRST
VSW = 2.4V
VBAT
VOUT
VBAT – 75mV
VBAT – 35mV
AI10463
Figure 27.
STM1403 switchover diagram, condition B (VBAT > VSW)
VCC = 3.3V
VOUT
VBAT
VSW = 2.4V
VSW + 40mV
AI10464
24/35