TDA7563PD
Diagnostics functional description
3
Diagnostics functional description
3.1
Turn-on diagnostic
It is activated at the turn-on (standby out) under I2C bus request. Detectable output faults
are:
– SHORT TO GND
– SHORT TO Vs
– SHORT ACROSS THE SPEAKER
– OPEN SPEAKER
To verify if any of the above misconnections are in place, a subsonic (inaudible) current
) pulse (Figure 18) is internally generated, sent through the speaker(s) and sunk back.The
t(s Turn On diagnostic status is internally stored until a successive diagnostic pulse is
c requested (after a I2C reading).
du If the "standby out" and "diagnostic enable" commands are both given through a single
ro ) programming step, the pulse takes place first (power stage still in standby mode, low,
P t(s outputs = high impedance).
te c Afterwards, when the amplifier is biased, the PERMANENT diagnostic takes place. The
le u previous Turn On state is kept until a short appears at the outputs.
so rod Figure 18. Turn-on diagnostic: working principle
) - Ob lete P Vs~5V
ct(s bso Isource
rodu ) - O CH+
P t(s CH-
solete roduc Isink
I (mA)
Isource
Isink
~100mS
Measure time
t (ms)
Ob solete P Figure 19 and 20 show SVR and OUTPUT waveforms at the turn-on (standby out) with and
Ob without TURN-ON DIAGNOSTIC.