DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TDA9111 View Datasheet(PDF) - STMicroelectronics

Part Name
Description
Manufacturer
TDA9111 Datasheet PDF : 43 Pages
First Prev 21 22 23 24 25 26 27 28 29 30 Next Last
TDA9111
2.3 PLL2
PLL2 ensures a constant position of the shaped
flyback signal in comparison with the sawtooth of
the VCO, taking into account the saturation time
Ts (see Figure 11)
Figure 11. PLL2 Timing Diagram
HOsc
Sawtooth
7/8TH
1/8 TH
6.4V
4.0V
1.6V
Flyback
Internally
shaped Flyback
The maximum storage time (Ts Max.) is (0.44TH-
TFLY/2). Typically, TFLY/TH is around 20 %, at
maximum frequency, which means that Ts max is
around 34 % of TH.
2.4 Output Section
The H-drive signal is sent to the output through a
shaping stage which also controls the H-drive duty
cycle (I2C adjustable) (see Figure 11). In order to
secure the scanning power part operation, the out-
put is inhibited in the following cases:
– when VCC or VDD are too low
– when the XRAY protection is activated
– during the Horizontal flyback
– when the HDrive I2C bit control is off.
The output stage consists of a NPN bipolar tran-
sistor. Only the collector is accessible (see
Figure 13).
Figure 13.
HDrive
Ts
Duty Cycle
The phase comparator of PLL2 is followed by a
charge pump (typical output current: 0.5 mA).
The flyback input consists of an NPN transistor.
The input current must be limited to less than 5 mA
(see Figure 12).
Figure 12. Flyback Input Electrical Diagram
HFLY 12
500
Q1
20k
GND 0V
The duty cycle is adjustable through I2C from 30 %
to 65 %. For a safe start-up operation, the initial
duty cycle (after power-on reset) is 65% in order to
avoid having too long a conduction period of the
horizontal scanning transistor.
This output stage is intended for “reverse” base
control, where setting the output NPN in off-state
will control the power scanning transistor in off-
state.
The maximum output current is 30mA, and the
corresponding voltage drop of the output VCEsat is
0.4V Max.
Obviously the power scanning transistor cannot be
directly driven by the integrated circuit. An inter-
face has to be added between the circuit and the
power transistor either of bipolar or MOS type.
2.5 X-RAY Protection
The X-Ray protection is activated by application of
a high level on the X-Ray input (more than 8.2V on
Pin 25). It inhibits the H-Drive and B+ outputs.
This activation is internally delayed by 2 lines to
avoid erratic detection when short parasitics are
present .
27/43