Functional check
4
Functional check
AN3233
Steady-state operation
In Figure 7 some waveforms relevant to the resonant stage during steady-state operation
are given. The selected switching frequency is about 120 kHz, in order to have a good trade
off between transformer losses and dimensions. The converter operates slightly above the
resonance frequency.
Figure 8 shows the key signals of SRK2000: each rectifier MOSFET is switched on and off
according to its drain-source voltage which, during conduction time, is the voltage image of
the current flowing through the MOSFET.
Figure 7. Resonant stage waveforms
at 115 V – 60 Hz – full load
Figure 8. SRK2000 key signals
at 115 V – 60 Hz – full load
CH1: HB voltage
CH2: CF pin voltage
CH4: Res. tank current
CH1: GD1 pin voltage
CH3: GD2 pin voltage
CH2: DVS1 pin
CH4: DVS2 pin
14/35
Doc ID 17595 Rev 1