DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

EVL150W-ADP-SR View Datasheet(PDF) - STMicroelectronics

Part Name
Description
Manufacturer
EVL150W-ADP-SR Datasheet PDF : 35 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
AN3233
Main characteristics and circuit description
the minimum switching frequency. The R-C series R44 and C18 sets both soft-start
maximum frequency and duration.
L6599A overload and short-circuit protection
The current into the primary winding is sensed by the loss-less circuit R41, C27, D11, D10,
R39, and C25 and it is fed into the ISEN pin (pin 6). In the case of overcurrent, the voltage
on the pin overpasses an internal threshold (0.8 V) that triggers a protection sequence. The
capacitor (C45) connected to the DELAY pin (pin 2) is charged by an internal 150 µA current
generator and is slowly discharged by the external resistor (R24). If the voltage on the pin
reaches 2 V, the soft-start capacitor is completely discharged so that the switching
frequency is pushed to its maximum value. As the voltage on the pin exceeds 3.5 V the IC
stops switching and the internal generator is turned off, so that the voltage on the pin decays
because of the external resistor. The IC is soft-restarted as the voltage drops below 0.3 V. In
this way, under short-circuit conditions, the converter works intermittently with very low input
average power.
Open loop protection
Both circuit stages, PFC and resonant, are equipped with their own overvoltage protections.
The PFC controller L6563H monitors its output voltage via the resistor divider connected to
a dedicated pin (PFC_OK, pin 7) protecting the circuit in case of loop failures or
disconnection. If a fault condition is detected, the internal circuitry latches the L6563H
operations and, by means of the PWM_LATCH pin (pin 8), it also latches the L6599A via the
DIS pin (pin 8). The converter is kept latched by the L6563H internal HV start-up circuit that
supplies the IC by charging the Vcc capacitor periodically. To resume converter operation, a
mains restart is necessary.
The output voltage is monitored by sensing the Vcc voltage. If Vcc voltage overrides the D12
breakdown voltage, Q9 pulls down the L6563H INV pin latching the converter.
Doc ID 17595 Rev 1
9/35

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]