DC and AC parameters
4
DC and AC parameters
M27C2001
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics Tables that
follow, are derived from tests performed under the Measurement Conditions summarized in
Table 5, Operating and AC Measurement Conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Table 5. AC Measurement conditions
High Speed
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
≤10ns
0 to 3V
1.5V
Table 6.
Symbol
Capacitance (1) (TA = 25°C, f = 1 MHz)
Parameter
Test Condition
CIN
Input Capacitance
COUT
Output Capacitance
1. Sampled only, not 100% tested
VIN = 0V
VOUT = 0V
Standard
≤20ns
0.4V to 2.4V
0.8V and 2V
Min Max Unit
6
pF
12
pF
Figure 6. AC Testing Input Output Waveform
High Speed
3V
0V
Standard
2.4V
0.4V
1.5V
2.0V
0.8V
AI01822
13/25