M27C2001
DC and AC parameters
Table 10. Read Mode AC Characteristics (1)
(TA = 0 to 70°C or –40 to 85°C; VCC = 5V ± 5% or 5V ± 10%; VPP = VCC)
M27C2001
Symbol Alt
Parameter Test Condition
-10
-12
-15/-20/-25 Unit
Min Max Min Max Min Max
tAVQV tACC Address Valid to E = VIL, G = VIL
100
120
Output Valid
150 ns
tELQV
tCE Chip Enable Low
to Output Valid
G = VIL
100
120
150 ns
tGLQV
tOE Output Enable
Low to Output
Valid
tEHQZ (2) tDF Chip Enable
High to Output
Hi-Z
tGHQZ (2) tDF Output Enable
High to Output
Hi-Z
E = VIL
50
50
60 ns
G = VIL
0 30 0 40 0 50 ns
E = VIL
0 30 0 40 0 50 ns
tAXQX tOH Address
E = VIL, G = VIL 0
0
0
ns
Transition to
Output Transition
1. VCC must be applied simultaneously with or before VPP and removed simultaneously or after VPP.
2. Sampled only, not 100% tested.
16/25