Data Sheet
In cases where the board temperature is known, the thermal
characterization parameter, ΨJB, can be used to estimate the
junction temperature rise. Maximum junction temperature (TJ)
is calculated from the board temperature (TB) and power
dissipation (PD) using the following formula:
TJ = TB + (PD × ΨJB)
(7)
Figure 42 through Figure 45 show junction temperature calcula-
tions for different board temperatures, load currents, VIN to
VOUT differentials, and areas of PCB copper.
140
MAX JUNCTION
TEMPERATURE
120
100
LOAD = 800mA
80
60
LOAD = 400mA
LOAD = 200mA
40
20
LOAD = 100mA
LOAD = 50mA
LOAD = 10mA
0
0.25
0.75
1.25
1.75
2.25
2.75
VIN – VOUT (V)
Figure 42. 500 mm2 of PCB Copper, TB = 25°C, LFCSP
140
MAX JUNCTION
TEMPERATURE
120
LOAD = 800mA
100
LOAD = 400mA
80
LOAD = 200mA
60
40
LOAD = 100mA
LOAD = 50mA
LOAD = 10mA
20
0
0.25
0.75
1.25
1.75
2.25
2.75
VIN – VOUT (V)
Figure 43. 500 mm2 of PCB Copper, TB = 50°C, LFCSP
ADP1752/ADP1753
140
MAX JUNCTION
TEMPERATURE
120
100
LOAD = 800mA
80
LOAD = 400mA
60
LOAD = 200mA
40
20
LOAD = 100mA
LOAD = 50mA
0
LOAD = 10mA
0.25
0.75
1.25
1.75
2.25
2.75
VIN – VOUT (V)
Figure 44. 1000 mm2 of PCB Copper, TB = 25°C, LFCSP
140
MAX JUNCTION
TEMPERATURE
120
LOAD = 800mA
100
80
LOAD = 400mA
LOAD = 200mA
60
40
LOAD = 100mA
LOAD = 50mA
LOAD = 10mA
20
0
0.25
0.75
1.25
1.75
2.25
2.75
VIN – VOUT (V)
Figure 45. 1000 mm2 of PCB Copper, TB = 50°C, LFCSP