First Prev 141 142 143 144 145 146 147 148 149 150 Next Last
The device uses the USB communication device class (CDC) drivers to take advantage of the installed PC RS-232
software to talk over the USB. The CDC class is implemented in all releases of Windows®, from Windows98SE to
WindowsXP. The CDC document, available at www.usb.org, describes a way to implement devices such as ISDN
modems and virtual COM ports.
The Vendor ID is Atmel’s vendor ID 0x03EB. The product ID is 0x6124. These references are used by the host
operating system to mount the correct driver. On Windows systems, the INF files contain the correspondence
between vendor ID and product ID.
21.5.3.1 Enumeration Process
The USB protocol is a master/slave protocol. This is the host that starts the enumeration sending requests to the
device through the control endpoint. The device handles standard requests as defined in the USB Specification.
Table 21-2. Handled Standard Requests
Request
Definition
GET_DESCRIPTOR
Returns the current device configuration value.
SET_ADDRESS
Sets the device address for all future device access.
SET_CONFIGURATION
Sets the device configuration.
GET_CONFIGURATION
Returns the current device configuration value.
GET_STATUS
Returns status for the specified recipient.
SET_FEATURE
Used to set or enable a specific feature.
CLEAR_FEATURE
Used to clear or disable a specific feature.
The device also handles some class requests defined in the CDC class.
Table 21-3. Handled Class Requests
Request
Definition
SET_LINE_CODING
Configures DTE rate, stop bits, parity and number of
character bits.
GET_LINE_CODING
Requests current DTE rate, stop bits, parity and number
of character bits.
SET_CONTROL_LINE_STATE
RS-232 signal used to tell the DCE device the DTE
device is now present.
Unhandled requests are STALLed.
21.5.3.2 Communication Endpoints
There are two communication endpoints and endpoint 0 is used for the enumeration process. Endpoint 1 is a 64-
byte Bulk OUT endpoint and endpoint 2 is a 64-byte Bulk IN endpoint. SAM-BA Boot commands are sent by the
host through the endpoint 1. If required, the message is split by the host into several data payloads by the host
driver.
If the command requires a response, the host can send IN transactions to pick up the response.