DC and AC parameters
8
DC and AC parameters
M24C01/02-W M24C01/02-R M24C02-F
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Table 5. Operating conditions (voltage range W)
Symbol
Parameter
Min.
Max.
Unit
VCC
Supply voltage
TA
Ambient operating temperature
fC
Operating clock frequency
2.5
5.5
V
–40
85
°C
-
400
kHz
Table 6. Operating conditions (voltage range R)
Symbol
Parameter
Min.
Max.
Unit
VCC
Supply voltage
TA
Ambient operating temperature
fC
Operating clock frequency
1.8
5.5
V
–40
85
°C
-
400
kHz
Table 7. Operating conditions (voltage range F,
for devices identified by process letter T)
Symbol
Parameter
Min.
VCC Supply voltage
Ambient operating temperature: READ
TA
Ambient operating temperature: WRITE
1.60 1.65 1.70
-40 -40 -40
0
-20 -40
fC
Operating clock frequency
-
-
-
Max. Unit
5.5
V
85
°C
85
400
kHz
Table 8. Operating conditions (voltage range F, for all other devices)
Symbol
Parameter
Min.
Max.
Unit
VCC Supply voltage
TA
Ambient operating temperature
fC
Operating clock frequency
1.7
5.5
V
-20
85
°C
-
400
kHz
20/34