ST72324Lxx
SUPPLY CURRENT CHARACTERISTICS (Cont’d)
12.4.2 Supply and Clock Managers
The previous current consumption specified for the ST7 functional operating modes over temperature
range does not take into account the clock source current consumption. To get the total device consump-
tion, the two current values must be added (except for HALT mode).
Symbol
Parameter
Conditions
Typ Max 1) Unit
IDD(RCINT) Supply current of internal RC oscillator
IDD(RES) Supply current of resonator oscillator 2) & 3)
IDD(PLL) PLL supply current
625
see Section
µA
12.5.3 on page
117
180
µA
Notes:
1. Data based on characterization results, not tested in production.
2. Data based on characterization results done with the external components specified in Section 12.5.3 , not tested in
production.
3. As the oscillator is based on a current source, the consumption does not depend on the voltage.
12.4.3 On-Chip Peripherals
TA = 25°C fCPU=4MHz.
Symbol
IDD(TIM)
IDD(SPI)
IDD(ADC)
Parameter
16-bit Timer supply current 1)
SPI supply current 2)
ADC supply current when converting 3)
Conditions
VDD=3.3V
Typ
Unit
20
250
µA
300
Notes:
1. Data based on a differential IDD measurement between reset configuration (timer counter running at fCPU/4) and timer
counter stopped (only TIMD bit set). Data valid for one timer.
2. Data based on a differential IDD measurement between reset configuration (SPI disabled) and a permanent SPI master
communication at maximum speed (data sent equal to 55h). This measurement includes the pad toggling consump-
tion.
3. Data based on a differential IDD measurement between reset configuration and continuous A/D conversions.
115/154