DC and AC parameters
M41T81
Table 11. Power down/up AC characteristics
Symbol
Parameter(1) (2)
Min
Typ
Max
Unit
tPD
SCL and SDA at VIH before power down
0
trec
SCL and SDA at VIH after power Up
10
1. VCC fall time should not exceed 5mV/µs.
2. Valid for Ambient Operating Temperature: TA = –40 to 85°C; VCC = 2.0 to 5.5V (except where noted).
Table 12. Power down/up trip points DC characteristics
Sym
Parameter(1) (2)
Min
Typ
nS
µS
Max
Unit
VSO Battery back-up switchover voltage
VBAT – 0.80 VBAT – 0.50 VBAT – 0.30 V
1. All voltages referenced to VSS.
2. Valid for Ambient Operating Temperature: TA = –40 to 85°C; VCC = 2.0 to 5.5V (except where noted).
Figure 16. Bus timing requirements sequence
SDA
tBUF
SCL
P
tHD:STA
tR
tF
tHIGH
S
tLOW
tSU:DAT
tHD:DAT
tHD:STA
tSU:STA
SR
tSU:STO
P
AI00589
24/30