M41T81
DC and AC parameters
Table 13. AC characteristics
Sym
Parameter(1)
Min
Typ
fSCL SCL clock frequency
0
tLOW Clock low period
1.3
tHIGH Clock high period
600
tR
SDA and SCL rise time
tF
SDA and SCL fall time
START condition hold time
tHD:STA (after this period the first clock pulse is
600
generated)
START condition setup time
tSU:STA (only relevant for a repeated start condition)
600
tSU:DAT Data setup time
100
tHD:DAT(2) Data hold time
0
tSU:STO STOP condition setup time
600
Time the bus must be free before a new
tBUF
transmission can start
1.3
1. Valid for Ambient Operating Temperature: TA = –40 to 85°C; VCC = 2.0 to 5.5V (except where noted).
2. Transmitter must internally provide a hold time to bridge the undefined region (300ns max) of the falling edge of SCL.
Max
400
300
300
Units
kHz
µs
ns
ns
ns
ns
ns
ns
µs
ns
µs
25/30