Table 43. Current consumption in Stop 2 mode (continued)
Symbol Parameter
Conditions
TYP
MAX(1)
Unit
-
VDD 0 °C 25 °C 40 °C 55 °C 85 °C 105 °C 0 °C 25 °C 85 °C 105 °C
Wakeup clock is
HSI16, voltage 3.0 V - 389 -
-
-
-
-
-
-
-
Range 2. See(4).
IDD
(wakeup
from
Stop 2)
Supply current
duringï€
wakeup fromï€
Stop 2 modeï€
bypass mode
Wakeup clock is
MSI = 32 MHz,
voltage
Range 1. See(4).
Wakeup clock is
3.0 V
-
320
-
-
-
MSI = 4 MHz,
voltage
3.0 V
-
528
-
-
-
Range 2. See(4).
-
-
-
-
-
-
-
-
-
µA
-
1. Guaranteed based on test during characterization, unless otherwise specified.
2. LCD enabled with external voltage source. Consumption from VLCD excluded. Refer to LCD controller characteristics for IVLCD
3. Based on characterization done with a 32.768 kHz crystal (MC306-G-06Q-32.768, manufacturer JFVNY) with two 6.8 pF loading
capacitors.
4. Wakeup with code execution from Flash memory. Average value given for a typical wakeup time as specified in Table 51: Low-power mode