DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

M25P10-AVMP6GX データシートの表示(PDF) - Numonyx -> Micron

部品番号
コンポーネント説明
メーカー
M25P10-AVMP6GX Datasheet PDF : 51 Pages
First Prev 41 42 43 44 45 46 47 48 49 50
DC and AC parameters
M25P10-A
Table 20.
AC characteristics (50 MHz operation, device grade 6)
50 MHz available only in products with process technology code Y(1)(2)
Test conditions specified in Table 10 and Table 12
Symbol Alt.
Parameter
Min Typ Max Unit
Clock frequency(1) for the following instructions:
fC
fC FAST_READ, PP, SE, BE, DP, RES, WREN, WRDI, D.C.
RDID, RDSR, WRSR
50 MHz
fR
tCH(3)
tCL(3)
tCLCH(4)
tCHCL(4)
tSLCH
tCHSL
tDVCH
tCHDX
tCHSH
tSHCH
tSHSL
tSHQZ(4)
tCLQV
tCLQX
tHLCH
tCHHH
tHHCH
tCHHL
tHHQX(4)
tHLQZ(4)
tWHSL(6)
tSHWL(6)
tDP(4)
tRES1(4)
Clock frequency for READ instructions
tCLH Clock High time
tCLL Clock Low time
Clock Rise time(5) (peak to peak)
Clock Fall time(5) (peak to peak)
tCSS S Active Setup time (relative to C)
S Not Active Hold time (relative to C)
tDSU
tDH
Data In Setup time
Data In Hold time
S Active Hold time (relative to C)
S Not Active Setup time (relative to C)
tCSH
tDIS
tV
tHO
S Deselect time
Output Disable time
Clock Low to Output Valid
Output Hold time
HOLD Setup time (relative to C)
HOLD Hold time (relative to C)
HOLD Setup time (relative to C)
HOLD Hold time (relative to C)
tLZ HOLD to Output Low-Z
tHZ HOLD to Output High-Z
Write Protect Setup time
Write Protect Hold time
S High to Deep Power-down mode
S High to Standby mode without Read Electronic
Signature
D.C.
9
9
0.1
0.1
5
5
2
5
5
5
100
0
5
5
5
5
20
100
25 MHz
ns
ns
V/ns
V/ns
ns
ns
ns
ns
ns
ns
ns
8 ns
8 ns
ns
ns
ns
ns
ns
8 ns
8 ns
ns
ns
3 μs
30 μs
tRES2(4)
S High to Standby mode with Read Electronic
Signature
30 μs
1. Details of how to find the process on the device marking are given in application note AN1995.
2. 50 MHz operation is also available in products with process technology code X, but with a reduced supply
voltage range (2.7 to 3.6 V).
3. tCH + tCL must be greater than or equal to 1/ fC.
4. Value guaranteed by characterization, not 100% tested in production.
5. Expressed as a slew-rate.
6. Only applicable as a constraint for a WRSR instruction when SRWD is set at ‘1’.
42/51