LINSCI™ SERIAL COMMUNICATION INTERFACE (LIN Mode) (cont’d)
Figure 69. LDIV Read / Write Operations When LDUM = 0
Write LPR Write LPFR
MANT(7:0) FRAC(3:0) LDIV_NOM
LIN Sync Field
Measurement
Write LPR
MANT(7:0) FRAC(3:0) LDIV_MEAS
Update
at end of
Synch Field
MANT(7:0) FRAC(3:0) LDIV
Baud Rate
Generation
Read LPR Read LPFR
Figure 70. LDIV Read / Write Operations When LDUM = 1
Write LPR Write LPFR
MANT(7:0) FRAC(3:0) LDIV_NOM
LIN Sync Field
Measurement
RDRF = 1
MANT(7:0) FRAC(3:0) LDIV_MEAS
Update
at end of
Synch Field
MANT(7:0) FRAC(3:0) LDIV
Baud Rate
Generation
Read LPR Read LPFR