DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

PIC16F1503T-I 查看數據表(PDF) - Microchip Technology

零件编号
产品描述 (功能)
生产厂家
PIC16F1503T-I
Microchip
Microchip Technology 
PIC16F1503T-I Datasheet PDF : 352 Pages
First Prev 111 112 113 114 115 116 117 118 119 120 Next Last
15.2 ADC Operation
15.2.1 STARTING A CONVERSION
To enable the ADC module, the ADON bit of the
ADCON0 register must be set to a ‘1’. Setting the GO/
DONE bit of the ADCON0 register to a ‘1’ will start the
Analog-to-Digital conversion.
Note:
The GO/DONE bit should not be set in the
same instruction that turns on the ADC.
Refer to Section 15.2.6 “ADC Conver-
sion Procedure”.
15.2.2 COMPLETION OF A CONVERSION
When the conversion is complete, the ADC module will:
• Clear the GO/DONE bit
• Set the ADIF Interrupt Flag bit
• Update the ADRESH and ADRESL registers with
new conversion result
15.2.3 TERMINATING A CONVERSION
If a conversion must be terminated before completion,
the GO/DONE bit can be cleared in software. The
ADRESH and ADRESL registers will be updated with
the partially complete Analog-to-Digital conversion
sample. Incomplete bits will match the last bit
converted.
Note:
A device Reset forces all registers to their
Reset state. Thus, the ADC module is
turned off and any pending conversion is
terminated.
PIC16(L)F1503
15.2.4 ADC OPERATION DURING SLEEP
The ADC module can operate during Sleep. This
requires the ADC clock source to be set to the FRC
option. Performing the ADC conversion during Sleep
can reduce system noise. If the ADC interrupt is
enabled, the device will wake-up from Sleep when the
conversion completes. If the ADC interrupt is disabled,
the ADC module is turned off after the conversion com-
pletes, although the ADON bit remains set.
When the ADC clock source is something other than
FRC, a SLEEP instruction causes the present conver-
sion to be aborted and the ADC module is turned off,
although the ADON bit remains set.
15.2.5 AUTO-CONVERSION TRIGGER
The auto-conversion trigger allows periodic ADC mea-
surements without software intervention. When a rising
edge of the selected source occurs, the GO/DONE bit
is set by hardware.
The auto-conversion trigger source is selected with the
TRIGSEL<3:0> bits of the ADCON2 register.
Using the auto-conversion trigger does not assure
proper ADC timing. It is the user’s responsibility to
ensure that the ADC timing requirements are met.
See Table 15-2 for auto-conversion sources.
TABLE 15-2: AUTO-CONVERSION
SOURCES
Source Peripheral
Timer0
Timer1
Timer2
Comparator C1
Comparator C2
CLC1
CLC2
Signal Name
T0_overflow
T1_overflow
T2_match
C1OUT_sync
C2OUT_sync
LC1_out
LC2_out
2011-2015 Microchip Technology Inc.
DS40001607D-page 117

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]