Specifications GAL16LV8C
Absolute Maximum Ratings(1)
Recommended Operating Conditions
Supply voltage VCC ................................... –0.5 to +5.6V
Input voltage applied ................................ –0.5 to +5.6V
Off-state output voltage applied ............... –0.5 to +5.6V
Storage Temperature ................................ –65 to 150°C
Ambient Temperature with
Power Applied ........................................ –55 to 125°C
1.Stresses above those listed under the “Absolute Maximum
Ratings” may cause permanent damage to the device. These
are stress only ratings and functional operation of the device at
these or at any other conditions above those indicated in the
operational sections of this specification is not implied (while
programming, follow the programming specifications).
Commercial Devices:
Ambient Temperature (TA) ............................... 0 to 75°C
Supply voltage (VCC)
with Respect to Ground ......................... +3.0 to +3.6V
DC Electrical Characteristics
Over Recommended Operating Conditions (Unless Otherwise Specified)
SYMBOL PARAMETER
CONDITION
MIN. TYP.2 MAX. UNITS
VIL
Input Low Voltage
VIH
Input High Voltage
IIL
Input or I/O Low Leakage Current
0V ≤ VIN ≤ VIL (MAX.)
IIH
Input or I/O High Leakage Current
(VCC - 0.2)V ≤ VIN ≤ VCC
Vss – 0.5 —
2.0
—
—
—
—
—
VOL
Output Low Voltage
VCC ≤ VIN ≤ 5.25V
IOL = MAX. Vin = VIL or VIH
—
—
—
—
VOH Output High Voltage
IOL = 500 µA Vin = VIL or VIH
IOH = MAX. Vin = VIL or VIH
IOH = -500 µA Vin = VIL or VIH
—
—
2.4
—
Vcc-0.45 —
IOH = -100 µA Vin = VIL or VIH
Vcc-0.2 —
IOL
IOH
IOS1
Low Level Output Current
High Level Output Current
Output Short Circuit Current
—
—
—
—
VCC = 3.3V VOUT = 0.5V TA = 25°C
-10
—
COMMERCIAL
ICC
Operating Power
Supply Current
VIL = 0.0V VIH = 3.0V
ftoggle = 1MHz Outputs Open
—
45
0.8
V
5.25
V
-10
µA
10
µA
30
mA
0.4
V
0.2
V
—
V
—
V
—
V
8
mA
-4
mA
-60 mA
65
mA
1) One output at a time for a maximum duration of one second. Vout = 0.5V was selected to avoid test problems by tester ground
degradation. Characterized but not 100% tested.
2) Typical values are at Vcc = 3.3V and TA = 25 °C
12