DC and AC parameters
M41T00CAP
Table 7. DC characteristics
Sym
Parameter
Test condition(1)
Min
Typ
Max Unit
ILI Input leakage current
ILO Output leakage current
0V ≤ VIN ≤ VCC
0V ≤ VOUT ≤ VCC
-
±1
µA
-
±1
µA
ICC1 Supply current
ICC2 Supply current (standby)
Switch freq = 400 kHz
SCL = 0 Hz
All inputs
≥ VCC – 0.2 V
≤ VSS + 0.2 V
-
300
µA
-
70
µA
VIL Input low voltage
–0.3
-
0.3 VCC V
VIH Input high voltage
Output low voltage
VOL Output low voltage
(open drain)(2)
IOL = 3.0 mA
IOL = 10 mA
0.7 VCC
-
VCC + 0.3 V
-
0.4
V
-
0.4
V
Pull-up supply voltage
(open drain)(2)
-
5.5
V
1. Valid for ambient operating temperature: TA = 0 to 70 °C; VCC = 2.7 to 5.5 V (except where noted).
2. For FT/OUT pin (open drain).
Figure 13. Power down/up mode AC waveforms
VCC
VSO
tPD
SDA
SCL
DON'T CARE
tREC
AI00596
Table 8. Power down/up AC characteristics
Symbol
Parameter(1)(2)
Min
Typ
Max
tPD
SCL and SDA at VIH before power down
0
-
-
trec
SCL and SDA at VIH after power up
10
-
-
1. VCC fall time should not exceed 5 mV/µs.
2. Valid for ambient operating temperature: TA = 0 to 70 °C; VCC = 2.7 to 5.5 V (except where noted).
Unit
nS
µS
20/27
Doc ID 14557 Rev 5