C8051F060/1/2/3/4/5/6/7
Figure 5.15. ADC0 Data Word Example
16-bit ADC0 Data Word appears in the ADC0 Data Word Registers as follows:
Example: ADC0 Data Word Conversion Map, AIN0 Input in Single-Ended Mode
(AMX0SL = 0x00)
AIN0-AIN0G (Volts)
ADC0H:ADC0L
VREF * (65535/65536)
0xFFFF
VREF / 2
0x8000
VREF * (32767/65536)
0x7FFF
0
0x0000
Example: ADC0 Data Word Conversion Map, AIN0-AIN1 Differential Input Pair
(AMX0SL = 0x40)
AIN0-AIN1 (Volts)
ADC0H:ADC0L
VREF * (32767/32768)
0x7FFF
VREF / 2
0x4000
VREF * (1/32768)
0x0001
0
0x0000
-VREF * (1/32768)
0xFFFF
-VREF / 2
0xC000
-VREF
0x8000
Code = Vin × --G-----a---i--n--- × 2n ; ‘n’ = 16 for Single-Ended; ‘n’=15 for Differential.
VREF
64
Rev. 1.2