Table 8.1 - Sector Sizes
N
SECTOR SIZE
00
128 bytes
01
256 bytes
02
512 bytes
03
1024 bytes
..
...
07
16 Kbytes
Enhanced Super I/O Controller with Fast IR
Datasheet
The amount of data which can be handled with a single command to the FDC depends upon MT (multi-
track) and N (number of bytes/sector).
The Multi-Track function (MT) allows the FDC to read data from both sides of the diskette. For a particular
cylinder, data will be transferred starting at Sector 1, Side 0 and completing the last sector of the same
track at Side 1.
If the host terminates a read or write operation in the FDC, the ID information in the result phase is
dependent upon the state of the MT bit and EOT byte. Refer to Table 8.2.
At the completion of the Read Data command, the head is not unloaded until after the Head Unload Time
Interval (specified in the Specify command) has elapsed. If the host issues another command before the
head unloads, then the head settling time may be saved between subsequent reads.
If the FDC detects a pulse on the nINDEX pin twice without finding the specified sector (meaning that the
diskette's index hole passes through index detect logic in the drive twice), the FDC sets the IC code in
Status Register 0 to "01" indicating abnormal termination, sets the ND bit in Status Register 1 to "1"
indicating a sector not found, and terminates the Read Data Command.
After reading the ID and Data Fields in each sector, the FDC checks the CRC bytes. If a CRC error occurs
in the ID or data field, the FDC sets the IC code in Status Register 0 to "01" indicating abnormal
termination, sets the DE bit flag in Status Register 1 to "1", sets the DD bit in Status Register 2 to "1" if
CRC is incorrect in the ID field, and terminates the Read Data Command. Table 8.3 describes the effect
of the SK bit on the Read Data command execution and results. Except where noted in Table 8.3, the C or
R value of the sector address is automatically incremented (see Table 8.5).
Table 8.2 - Effects of MT and N Bits
MT N
MAXIMUM TRANSFER
CAPACITY
FINAL SECTOR READ
FROM DISK
0
1 256 x 26 = 6,656
26 at side 0 or 1
1
1 256 x 52 = 13,312
26 at side 1
0
2 512 x 15 = 7,680
15 at side 0 or 1
1
2 512 x 30 = 15,360
15 at side 1
0
3 1024 x 8 = 8,192
8 at side 0 or 1
1
3 1024 x 16 = 16,384
16 at side 1
SMSC FDC37C672
Page 50
DATASHEET
Rev. 10-29-03