M41ST85W
Figure 20. Power down/up mode AC waveforms
VCC
VPFD (max)
VPFD (min)
VSO
tF
tPD
PFO
tFB
tRB
tDR
DC and AC parameters
tR
trec
INPUTS
RECOGNIZED
RST
OUTPUTS
ECON
VALID
(PER CONTROL INPUT)
DON'T CARE
HIGH-Z
RECOGNIZED
VALID
(PER CONTROL INPUT)
AI03661
Table 13. Power down/up AC characteristics
Symbol
Parameter(1)
Min
Typ
Max
tF(2)
tFB(3)
tPD
tPFD
tR
tRB
trec(4)
VPFD(max) to VPFD(min) VCC Fall Time
VPFD(min) to VSS VCC Fall Time
EX at VIH before Power Down
PFI to PFO Propagation Delay
VPFD(min) to VPFD(max) VCC Rise Time
VSS to VPFD(min) VCC Rise Time
Power up Deselect Time
300
10
0
15
25
10
1
40
200
1. Valid for Ambient Operating Temperature: TA = –40 to 85°C; VCC = 2.7 to 3.6V (except where otherwise noted).
2. VPFD(max) to VPFD(min) fall time of less than tF may result in deselection/write protection not occurring until
200µs after VCC passes VPFD(min).
3. VPFD(min) to VSS fall time of less than tFB may cause corruption of RAM data.
4. Programmable (see Table 6 on page 28)
Unit
µs
µs
µs
µs
µs
µs
ms
33/41