System modules
1. To enter BDM mode following a POR, BKGD/MS should be held low during the power-up and for a hold time of tMSH after
VDD rises above VLVD.
6.2 System modules
6.2.1 VREG electrical specifications
Table 13. VREG electrical specifications
Symbol Description
VREGIN Input supply voltage
IDDon
Quiescent current — Run mode, load current
equal zero, input supply (VREGIN) > 3.6 V
IDDstby Quiescent current — Standby mode, load
current equal zero
IDDoff
Quiescent current — Shutdown mode
• VREGIN = 5.0 V and temperature=25C
• Across operating voltage and temperature
Min.
2.7
—
—
—
—
Typ.1
—
120
1.1
650
—
Max.
5.5
186
1.54
—
4
Unit
Notes
V
μA
μA
nA
μA
ILOADrun
ILOADstby
VReg33out
Maximum load current — Run mode
Maximum load current — Standby mode
Regulator output voltage — Input supply
(VREGIN) > 3.6 V
• Run mode
• Standby mode
VReg33out Regulator output voltage — Input supply
(VREGIN) < 3.6 V, pass-through mode
COUT External output capacitor
ESR
External output capacitor equivalent series
resistance
ILIM
Short circuit current
—
—
120
mA
—
—
1
mA
3
3.3
3.6
V
2.1
2.8
3.6
V
2.1
—
3.6
V
2
1.76
2.2
8.16
μF
1
—
100
mΩ
—
290
—
mA
1. Typical values assume VREGIN = 5.0 V, Temp = 25 °C unless otherwise stated.
2. Operating in pass-through mode: regulator output voltage equal to the input voltage minus a drop proportional to ILoad.
MCF51QM128 Data Sheet, Rev. 6, 01/2012.
22