ST92141 - ELECTRICAL CHARACTERISTICS
STANDARD TIMER TIMING TABLE
(VDD = 5V ± 10%, TA = –40°C to +85°C, CLoad = 50pF, fINTCLK = 25MHz, Push-pull output configuration,
unless otherwise specified)
N° Symbol
Parameter
1 TwSTOL
STOUT Low Pulse Width
2 TwSTOH STOUT High Pulse Width
3 TwSTIL
4 TwSTIH
STIN High Pulse Width
STIN Low Pulse Width
Value (Note)
Formula(1)
Min
160
4 x (Psc+1) x (Cnt+1) x Tck
(Psc+1) x (Cnt+1) x TSTIN
320
with TSTIN ≥ 8 x Tck
160
4 x (Psc+1) x (Cnt+1) x Tck
(Psc+1) x (Cnt+1) x TSTIN
320
with TSTIN ≥ 8 x Tck
≥ 4 x Tck + 10
170
≥ 4 x Tck + 10
170
Unit
Max
ns
2.69
s
ns
ns
2.69
s
ns
ns
ns
Note: The value in the left hand column shows the formula used to calculate the timing minimum or maximum from the oscillator clock period,
standard timer prescaler and counter programmed values.
The value in the right hand two columns show the timing minimum and maximum for an internal clock (INTCLK) at 25MHz, with minimum and
maximum prescaler value and minimum and maximum counter value.
Measurement points are taken with reference to VIH-VIH / VOH-VOH for positive pulse and VIL-VIL / VOL-VOL for negative pulse
(1) Formula guaranteed by design.
Legend:
Tck = INTCLK period = OSCIN period when OSCIN is not divided by 2;
2 x OSCIN period when OSCIN is divided by 2;
OSCIN period x PLL factor when the PLL is enabled.
Psc = Standard Timer Prescaler Register content (STP): from 0 to 255
Cnt = Standard Timer Counter Registers content (STH,STL): from 0 to 65535
TSTIN = Standard Timer Input signal period (STIN).
STANDARD TIMER TIMING
165/179
1