STA328
Electrical specifications
Table 8.
Symbol
Power electrical characteristics (continued)
Parameter
Test conditions
Min. Typ. Max. Unit
Input pulse width = 50%
Supply current from VCC in
duty,
IVCC
operation
switching
80
(both channel switching)
frequency = 384 kHz,
no LC filters
Iout-sh
Overcurrent protection
threshold (short circuit current
limit)
4.5 6
VUV
Undervoltage protection
threshold
7
tpw-min Output minimum pulse width No load
70
THD = 10%
Po
Output power (refer to test
circuit
RL = 4Ω, VCC = 21 V
50
RL = 8Ω, VCC = 36 V
80
THD = 1%
Po
Output power (refer to test
circuit
RL = 4Ω, VCC = 21 V
40
RL = 8Ω, VCC = 36 V
62
mA
A
V
150 ns
W
W
W
W
Figure 7. Test circuit 1
OUTxY
Vcc
Low current dead time = MAX(DTr, DTf)
+Vcc
Duty cycle = 50%
INxY
M58
M57
OUTxY
gnd
(3/4)Vcc
(1/2)Vcc
(1/4)Vcc
t
DTr
DTf
R 8W
+-
V67
vdc = Vcc/2
Figure 8. Test circuit 2
High Current Dead time for Bridge application = ABS(DTout(A)-DTin(A))+ABS(DTOUT(B)-DTin(B))
+VCC
Duty cycle=A
DTin(A)
INA
DTout(A)
M58
Q1
Q2
M64
OUTA
Rload=4Ω
DTout(B)
OUTB
L67 10µ
Iout=1.5A
L68 10µ
Iout=1.5A
M57
Q3
C69
470nF
C71 470nF
C70
470nF
Q4
M63
Duty cycle=B
DTin(B)
INB
Duty cycle A and B: Fixed to have DC output current of 4A in the direction shown in figure
D06AU1651
13/57