Electrical characteristics
STM8S005K6 STM8S005C6
Symbol Parameter Conditions
IDD(RUN)
Supply
current in run
mode, code
executed
fromFlash
fCPU = fMASTER
= 16 MHz
HSE crystal osc.
(16 MHz)
HSE user ext. clock
(16 MHz)
Typ Max(1) Unit
7.7
7.0 8.0
HSI RC osc.
(16 MHz)
7.0 8.0
fCPU = fMASTER
HSI RC osc.
1.5
= 2 MHz
(16 MHz/8)(2)
fCPU = fMASTER/128 = HSI RC osc.
125 kHz
(16 MHz)
1.35 2.0
fCPU = fMASTER/128 = HSI RC osc.
0.75
15.625 kHz
(16 MHz/8)
fCPU = fMASTER
LSI RC osc.
0.6
= 128 kHz
(128 kHz)
(1) Data based on characterization results, not tested in production.
(2) Default clock configuration measured with all peripherals off.
Table 20: Total current consumption with code execution in run mode at VDD = 3.3 V
Symbol Parameter Conditions
Typ Max(1) Unit
IDD(RUN)
Supply
current
in run
mode,
code
executed
from
RAM
fCPU = fMASTER = 16 MHz
HSE crystal osc.
(16 MHz)
HSE user ext. clock
(16 MHz)
HSI RC osc.
(16 MHz)
2.8
mA
2.6 3.2
2.5 3.2
56/103
DocID022186 Rev 3