DC and AC parameters
5
DC and AC parameters
M41ST84W
Note:
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the Measurement Conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Table 10. DC and AC measurement conditions
Parameter
VCC supply voltage
Ambient operating temperature
Load capacitance (CL)
Input rise and fall times
Input pulse voltages
Input and output timing ref. voltages
Output Hi-Z is defined as the point where data is no longer driven.
M41ST84W
2.7 to 3.6 V
–40 to 85°C
50 pF
≤ 50 ns
0.2 to 0.8VCC
0.3 to 0.7VCC
Figure 17. AC testing input/output waveforms
0.8VCC
0.2VCC
0.7VCC
0.3VCC
AI02568
Note:
50 pF for M41ST84W.
Table 11. Capacitance
Symbol
Parameter(1)(2)
Min
Max
CIN Input capacitance
7
CIO(3) Input / output capacitance
10
tLP Low-pass filter input time constant (SDA and SCL)
50
1. Effective capacitance measured with power supply at 3 V. Sampled only, not 100% tested.
2. At 25°C, f = 1 MHz.
3. Outputs deselected.
Unit
pF
pF
ns
28/34