S25FL128S, S25FL256S
Table 9.2 S25FL128S and S25FL256S Command Set (sorted by function) (Continued)
Function
Command Name
Command Description
Erase Flash Array
One Time Program
Array
Advanced Sector
Protection
Reset
Reserved for Future
Use
RFU
RFU
RFU
P4E
4P4E
BE
BE
SE
4SE
ERSP
ERRS
OTPP
OTPR
DYBRD
DYBWR
PPBRD
PPBP
PPBE
ASPRD
ASPP
PLBRD
PLBWR
PASSRD
PASSP
PASSU
RESET
MBR
MPM
Reserved-18
Reserved-E5
Reserved-E6
Parameter 4-kB, sector Erase (3- or 4-byte address)
Parameter 4-kB, sector Erase (4-byte address)
Bulk Erase
Bulk Erase (alternate command)
Erase 64 kB or 256 kB (3- or 4-byte address)
Erase 64 kB or 256 kB (4-byte address)
Erase Suspend
Erase Resume
OTP Program
OTP Read
DYB Read
DYB Write
PPB Read
PPB Program
PPB Erase
ASP Read
ASP Program
PPB Lock Bit Read
PPB Lock Bit Write
Password Read
Password Program
Password Unlock
Software Reset
Mode Bit Reset
Reserved for Multi-I/O-High Perf Mode (MPM)
Reserved
Reserved
Reserved
Instruction
Value (Hex)
20
21
60
C7
D8
DC
75
7A
42
4B
E0
E1
E2
E3
E4
2B
2F
A7
A6
E7
E8
E9
F0
FF
A3
18
E5
E6
Maximum
Frequency
(MHz) (1)
133
133
133
133
133
133
133
133
133
133
133
133
133
133
133
133
133
133
133
133
133
133
133
133
133
Note:
1. For Industrial Plus (-40°C to +105°C) and Extended (-40°C to +125°C) temperature range, all Maximum Frequency values are 5% slower than the Max values shown.
9.1.2
Read Device Identification
There are multiple commands to read information about the device manufacturer, device type, and device features. SPI memories
from different vendors have used different commands and formats for reading information about the memories. The S25FL128S and
S25FL256S devices support the three most common device information commands.
9.1.3
Register Read or Write
There are multiple registers for reporting embedded operation status or controlling device configuration options. There are
commands for reading or writing these registers. Registers contain both volatile and non-volatile bits. Non-volatile bits in registers
are automatically erased and programmed as a single (write) operation.
Document Number: 001-98283 Rev. *I
Page 67 of 144