Electrical characteristics
Table 84. XAUI transmitter AC timing specifications1 (continued)
Parameter
Symbol
Total jitter
JT
Unit Interval: 3.125 GBaud
UI
Notes:
1. For recommended operating conditions, see Table 3.
Min
-
320 - 100 ppm
Typical
-
320
Max
0.35
320 + 100 ppm
Unit
UI p-p
ps
3.19.6.2.2 XAUI receiver AC timing specifications
This table defines the receiver AC specifications for XAUI. RefClk jitter is not included.
Table 85. XAUI receiver AC timing specifications1
Parameter
Symbol
Min
Typical
Max
Unit
Notes
Deterministic jitter tolerance
JD
-
Combined deterministic and random JDR
-
jitter tolerance
-
0.37
UI p-p
2
-
0.55
UI p-p
2
Total jitter tolerance
Bit error rate
JT
-
BER
-
-
0.65
UI p-p
2, 3
-
10-12
-
-
Unit Interval: 3.125 GBaud
UI
320 - 100 ppm 320
320 + 100 ppm ps
-
Notes:
1. For recommended operating conditions, see Table 3.
2. Measured at receiver
3. Total jitter is composed of three components: deterministic jitter, random jitter, and single frequency sinusoidal jitter. The
sinusoidal jitter may have any amplitude and frequency in the unshaded region of Figure 44. The sinusoidal jitter component
is included to ensure margin for low frequency jitter, wander, noise, crosstalk, and other variable system effects.
3.19.7 Aurora interface
This section describes the Aurora clocking requirements and its DC and AC electrical
characteristics.
3.19.7.1 Aurora clocking requirements for SDn_REF_CLKn_P and
SDn_REF_CLKn_N
Only SerDes 2 (SD2_REF_CLK[1:2]_P and SD2_REF_CLK[1:2]_N) may be used for
SerDes Aurora configurations based on the RCW Configuration field SRDS_PRTCL.
Aurora is not supported on SerDes 1-3.
For more information on these specifications, see SerDes reference clocks.
QorIQ T2080 Data Sheet, Rev. 3, 03/2018
NXP Semiconductors
127