DC and AC parameters
8
DC and AC parameters
M24M01-R M24M01-DF
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Table 6. Operating conditions (voltage range R)
Symbol
Parameter
Min.
VCC Supply voltage
1.8
TA
Ambient operating temperature
–40
fC
Operating clock frequency
-
Max.
5.5
85
1
Unit
V
°C
MHz
Table 7. Operating conditions (voltage range F)
Symbol
Parameter
Min.
VCC Supply voltage
1.7
TA
Ambient operating temperature
–40
fC
Operating clock frequency
-
Max.
5.5
85
1
Unit
V
°C
MHz
Table 8. AC measurement conditions
Symbol
Parameter
Cbus
Load capacitance
SCL input rise/fall time, SDA input fall time
Input levels
Input and output timing reference levels
Min.
Max.
100
-
50
0.2 VCC to 0.8 VCC
0.3 VCC to 0.7 VCC
Unit
pF
ns
V
V
Figure 11. AC measurement I/O waveform
)NPUT VOLTAGE LEVELS
6##
6##
)NPUT AND OUTPUT
4IMING REFERENCE LEVELS
6##
6##
Table 9.
Symbol
Input parameters
Parameter(1)
CIN Input capacitance (SDA)
CIN Input capacitance (other pins)
ZL
Input impedance (WC)
ZH
1. Sampled only, not 100% tested.
Test condition
VIN < 0.3 VCC
VIN > 0.7 VCC
Min.
30
400
-36
Max.
Unit
8
pF
6
pF
kΩ
kΩ
24/38