M24M01-R M24M01-DF
DC and AC parameters
Table 13. DC characteristics (M24M01-F, device grade 6)
Symbol
Parameter
Test conditions (in addition to
those in Table 6)
Min.
ILI
Input leakage current
(E1, E2, SCL, SDA)
VIN = VSS or VCC
device in Standby mode
ILO
Output leakage current
SDA in Hi-Z, external voltage
applied on SDA: VSS or VCC
VCC = 1.7 V, fc= 400 kHz
Max. Unit
±2
µA
±2
µA
1
mA
VCC = 2.5 V, fc =400 kHz
ICC Supply current (Read)
VCC = 5.5 V, fc =400 kHz
1
mA
1.5 mA
fc= 1 MHz
ICC0 Supply current (Write) During tW
Device not selected,
VIN = VSS or VCC, VCC = 1.7 V
ICC1
Standby supply current
Device not selected,
VIN = VSS or VCC, VCC = 2.5 V
Device not selected,
VIN = VSS or VCC, VCC = 5.5 V
VIL
Input low voltage
(SCL, SDA, WC)
1.7 V ≤ VCC < 2.5 V
2.5 V ≤ VCC < 5.5 V
VIH
Input high voltage
(SCL, SDA)
1.7 V ≤ VCC < 2.5 V
2.5 V ≤ VCC < 5.5 V
IOL = 1.0 mA, VCC = 1.7 V
VOL Output low voltage
IOL = 2.1 mA, VCC = 2.5 V
IOL = 3.0 mA, VCC = 5.5 V
1. Characterized only, not tested in production.
1.5 mA
2(1)
mA
3
µA
3
µA
5
µA
–0.45 0.25 VCC V
–0.45 0.30 VCC V
0.75 VCC VCC+1 v
0.70 VCC 0 VCC+1 v
0.2
V
0.4
V
0.4
V
Doc ID 12943 Rev 10
27/38