DC and AC parameters
8
DC and AC parameters
M24M01-R M24M01-DF
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Symbol
VCC
TA
fC
Table 6. Operating conditions (voltage range R)
Parameter
Min.
Max.
Supply voltage
1.8
5.5
Ambient operating temperature
–40
85
Operating clock frequency
-
1
Unit
V
°C
MHz
Table 7. Operating conditions (voltage range F)
Symbol
Parameter
Min.
Max.
VCC Supply voltage
TA
Ambient operating temperature
fC
Operating clock frequency
1.7
5.5
–40
85
-
1
Unit
V
°C
MHz
Symbol
Cbus
-
-
-
Table 8. AC measurement conditions
Parameter
Min.
Max.
Load capacitance
SCL input rise/fall time, SDA input fall time
Input levels
Input and output timing reference levels
0
100
-
50
0.2 VCC to 0.8 VCC
0.3 VCC to 0.7 VCC
Figure 11. AC measurement I/O waveform
)NPUT VOLTAGE LEVELS
6##
6##
)NPUT AND OUTPUT
4IMING REFERENCE LEVELS
6##
6##
Symbol
Table 9. Input parameters
Parameter(1)
Test condition
CIN Input capacitance (SDA)
CIN Input capacitance (other pins)
ZL
Input impedance (WC)
ZH
1. Sampled only, not 100% tested.
-
-
VIN < 0.3 VCC
VIN > 0.7 VCC
Min.
-
-
30
400
Max.
8
6
-
-
Unit
pF
ns
V
V
-36
Unit
pF
pF
kΩ
kΩ
24/47