M24M01-R M24M01-DF
DC and AC parameters
Symbol
Table 13. DC characteristics (M24M01-DF, device grade 6)
Parameter
Test conditions (in addition to
those in Table 6)
Min.
Max. Unit
ILI
Input leakage current
(E1, E2, SCL, SDA)
VIN = VSS or VCC
device in Standby mode
-
±2
µA
ILO
Output leakage current
SDA in Hi-Z, external voltage
applied on SDA: VSS or VCC
-
±2
µA
VCC = 1.7 V, fc= 400 kHz
-
1
mA
VCC = 2.5 V, fc =400 kHz
ICC Supply current (Read)
VCC = 5.5 V, fc =400 kHz
-
1
mA
-
1.5
mA
fc= 1 MHz
ICC0 Supply current (Write) During tW
Device not selected,
VIN = VSS or VCC, VCC = 1.7 V
ICC1
Standby supply current
Device not selected,
VIN = VSS or VCC, VCC = 2.5 V
Device not selected,
VIN = VSS or VCC, VCC = 5.5 V
VIL
Input low voltage
(Ei, SCL, SDA, WC)(2)
1.7 V ≤ VCC < 2.5 V
2.5 V ≤ VCC < 5.5 V
VIH
Input high voltage
(Ei, SCL, SDA, WC)(3)
1.7 V ≤ VCC < 2.5 V
2.5 V ≤ VCC < 5.5 V
IOL = 1.0 mA, VCC = 1.7 V
VOL Output low voltage
IOL = 2.1 mA, VCC = 2.5 V
IOL = 3.0 mA, VCC = 5.5 V
1. Characterized only, not tested in production.
2. Ei inputs should be tied to VSS (seeSection 2.3).
3. Ei inputs should be tied to Vcc (see Section 2.3).
-
1.5
mA
-
2(1)
mA
-
3
µA
-
3
µA
-
5
µA
–0.45 0.25 VCC V
–0.45 0.30 VCC V
0.75 VCC VCC+1
v
0.70 VCC VCC+1
v
-
0.2
V
-
0.4
V
-
0.4
V
DocID12943 Rev 14
27/47