DATA
0
1
0
1
0
IRRX
t1
t2
n IRRX
MIRRX
t3 t4
nMIRRX
t5 t6
0
1
1
0
1
1
Parameter
t1 Modulated Output Bit Time
t2 Off Bit Time
t3 Modulated Output "On"
t4 Modulated Output "Off"
t5 Modulated Output "On"
t6 Modulated Output "Off"
min
typ max
units
0.8
1
0.8
1
0.8
1
0.8
1
µs
µs
1.2
µs
1.2
µs
1.2
µs
1.2
µs
Notes:
1. IRRX: L5, CRF1 Bit 0: 1 = RCV active low
nIRRX: L5, CRF1 Bit 0: 0 = RCV active high (default)
MIRRX, nMIRRX are the modulated outputs
FIGURE 21 - AMPLITUDE SHIFT KEYED IR RECEIVE TIMING