Register Description by Block
ADE3800
Note:
Timeout and Tolerance use Horizontal and Vertical measurements. These can either be the
Horizontal or Vertical syncs from an Analog input or the local generated Horizontal Enable and/or
Vertical Enable.
Table 17: SMEAS Register Definitions (Sheet 1 of 6)
Register Name
Addr Mode Bits Rst
Description
SMEAS_ACT_CTRL
0100 R/W
R/W
R/W
R/W
SMEAS_ACT_H_SMPTM_L 0101 R/W
SMEAS_ACT_H_SMPTM_U 0102 R/W
SMEAS_ACT_V_SMPTM_L 0103 R/W
SMEAS_ACT_V_SMPTM_U 0104 R/W
SMEAS_ACT_H_MINEDGE 0105 R/W
SMEAS_ACT_V_MINEDGE 0106 R/W
SMEAS_H_TMOT_L
0107 R/W
SMEAS_H_TMOT_U
SMEAS_V_TMOT_L
0108 R/W
0109 R/W
SMEAS_V_TMOT_U
SMEAS_CLEAR
010A R/W
0110 R/W
[3]
00 Free-run enable
[2]
Freeze results during free run mode. No meaning in one shot
mode.
0*: Do not freeze. New result will be available on the next and
subsequent toggle of the polling bit.
1: Freeze the current results. The polling bit will still toggle
and the block continues to free run; however, results will not
update.
[1]
Activity detection start.
In one-shot mode setting this bit triggers the start of a
measurement. This bit is reset to zero when the
measurement is complete. No meaning in free run mode.
[0]
Activity detection mode.
0*: free-run mode
1: one-shot mode
[7:0] 00 Sample period value for clock or HSync activity. Xclks [7:0]
[7:0] 00 Sample period value for clock or HSync activity. Xclks [15:8]
[7:0] 00 Sample period value for vsync activity. Xclks / 256 [7:0]
[7:0] 00 Sample period value for vsync activity. Xclks / 256 [15:8]
[7:0] 00 Minimum edge count value for clk or HSync activity.
[7:0] 00 Minimum edge count value for vsync activity.
[7:0] 00 Timeout counter value for clk or horizontal measurement.
xclks [7:0]
[7:0] 00 Timeout counter value for clk or horizontal measurement.
xclks [15:8]
[7:0] 00 Timeout counter value for vertical measurement. xclks / 256
[7:0]
[7:0] 00 Timeout counter value for vertical measurement. xclks / 256
[15:8]
[1]
00 clears SMEAS_STATUS_RANGE[7] sticky bit only.
Must be reset by software.
[0]
clears timeouts, measurements.
Must be reset by software.
38/138