Si3232
Table 5. Linefeed Characteristics
(VDD, VDD1–VDD4 = 3.13 to 3.47 V, TA = 0 to 70 °C for K-Grade, –40 to 85 °C for B-Grade)
Parameter
Symbol
Test Condition
Min Typ Max Unit
DC Loop Current Accuracy
ILIM = 18 mA
— ±10
%
DC Open Circuit Voltage
Accuracy
Active Mode; VOC = 48 V,
VTIP – VRING
±4
V
DC Differential Output
RDO
Resistance
ILOOP < ILIM
— 320 —
DC On-Hook Voltage
VOHTO
IRING<ILIM; VRING wrt ground
±4
V
Accuracy—Ground Start
VRING = –51 V
DC Output Resistance—
RROTO
IRING<ILIM; RING to ground
— 320 —
Ground Start
DC Output Resistance—
Ground Start
RTOTO
TIP to ground
300 —
k
Loop Closure Detect
Threshold Accuracy
ITHR = 13 mA
— ±10 ±15
%
Ground Key Detect
Threshold Accuracy
ITHR = 13 mA
— ±10 ±15
%
Ring Trip Threshold
Accuracy
Ringing Amplitude*
Sinusoidal Ringing Total
Harmonic Distortion
ac Detection, VRING = 70 VPK,
±4
±5
mA
ITH = 80 mA
VRING
dc detection,
20 V dc offset, ITH = 13 mA
Open circuit, VBATH = 100 V
5 REN load, RLOOP = 0 Ω,
VBATH = 100 V
— ±1.5 ±2
mA
93
VPK
82
VPK
RTHD
2
%
Ringing Frequency Accuracy
f = 16 Hz to 100 Hz
±1
%
Ringing Cadence Accuracy
Accuracy of ON/OFF times
— ±50
ms
Calibration Time
CAL to CAL bit
— 600
ms
Loop Voltage Sense
Accuracy
Accuracy of boundaries for each —
±2
±4
%
output Code;
VTIP – VRING = 48 V
Loop Current Sense
Accuracy
Accuracy of boundaries for each —
±7 ±10
%
output code;
ILOOP = 18 mA
Power Alarm Threshold
Accuracy
Power Threshold = 300 mW
— ±25
%
*Note: Ringing amplitude is set for 93 V peak using the RINGAMP RAM address and measured at TIP-RING using no series
protection resistance.
10
Preliminary Rev. 0.96