Application information
TS2007FC
Table 12. Example of component choice
Component
RL = 4 Ω
L1
15μH / 1.4A
L2
15μH / 1.4A
C1
2μF / 10V
C2
2μF / 10V
C3
1μF / 10V
R
22Ω / 0.25W
Figure 46. LC output filter with RC network
OUT+
from TS2007
LC Output Filter
L1 C1
OUT-
L2 C2
RL = 8 Ω
30μH / 0.7A
30μH / 0.7A
1μF / 10V
1μF / 10V
1μF / 10V
47Ω / 0.25W
RC network
C3
RL
R
4.11
Short-circuit protection
The TS2007 includes an output short-circuit protection. This protection prevents the device
from being damaged if there are fault conditions on the amplifier outputs.
When a channel is in operating mode and a short-circuit occurs directly between two
outputs (Out+ and Out-) or between an output and ground (Out+ and GND or Out- and
GND), the short-circuit protection detects this situation and puts the amplifier into standby.
To put the amplifier back into operating mode, put the standby pin to logical LO and then to
logical HI.
4.12
Thermal shutdown
The TS2007 device has an internal thermal shutdown protection in the event of extreme
temperatures to protect the device from overheating. Thermal shutdown is active when the
device reaches 150°C. When the temperature decreases to safe levels, the circuit switches
back to normal operation.
24/28