STPS1L40
Characteristics
Figure 13. Reverse leakage current versus
reverse voltage applied
(typical values)
1.E+02 IR(mA)
1.E+01
1.E+00
1.E-01
1.E-02
1.E-03
0
5
Tj = 150 °C
Tj = 125 °C
Tj = 100 °C
Tj = 75 °C
Tj = 50 °C
Tj = 25 °C
10 15 20 25
VR(V)
30
35
40
Figure 14. Junction capacitance versus
reverse voltage applied
(typical values)
C(pF)
1000
F = 1 MHz
Vosc = 30 mVRMS
Tj = 25 °C
100
10
VR(V)
1
10
100
Figure 15. Forward voltage drop versus
forward current
(typical values, high level)
10.00 IFM(A)
1.00
Tj = 125 °C
Tj = 25 °C
0.10
VFM(V)
0.01
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2
Figure 16. Forward voltage drop versus
forward current
(typical values, low level)
3.0 IFM(A)
2.5
2.0
Tj = 125 °C
1.5
Tj = 25 °C
1.0
0.5
0.0
VFM(V)
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
Doc ID 5507 Rev 6