Electrical characteristics
STM8S007C8
Static latch-up
Two complementary static tests are required on 10 parts to assess the latch-up
performance:
ï‚· A supply overvoltage (applied to each power supply pin)
ï‚· A current injection (applied to each input, output and configurable I/O pin) is performed
on each sample.
This test conforms to the EIA/JESD 78 IC latch-up standard. For more details, refer to the
application note AN1181.
Symbol
Table 48. Electrical sensitivities
Parameter
Conditions
Class(1)
TA ï€½ï€ 25 °C
A
LU Static latch-up class
TA ï€½ï€ 85 °C
A
1. Class description: A Class is an STMicroelectronics internal specification. All its limits are higher than the
JEDEC specifications, that means when a device belongs to class A it exceeds the JEDEC standard. B
class strictly covers all the JEDEC criteria (international standard).
82/92