Register description
STA335BWS
6.1.2 Interpolation ratio select
6.1.3
Bit R/W RST
4:3 R/W
00
Name
IR[1:0)
Description
Selects internal interpolation ratio based on input I2S
sample frequency
The STA335BWS has variable interpolation (oversampling) settings such that internal
processing and DDX output rates remain consistent. The first processing block interpolates
by either 2 times or 1 time (pass-through) or provides a 2 times downsample. The
oversampling ratio of this interpolation is determined by the IR bits.
Table 11. IR bit settings as a function of input sample rate
Input sample rate Fs (kHz)
IR
1st stage interpolation ratio
32
00
2 times oversampling
44.1
00
2 times oversampling
48
00
2 times oversampling
88.2
01
Pass-through
96
01
Pass-through
176.4
10
2 times downsampling
192
10
2 times downsampling
Thermal warning recovery bypass
Bit R/W RST
Name
Description
5
R/W
1
TWRB
0: Thermal warning recovery enabled
1: Thermal warning recovery disabled
If the thermal warning adjustment is enabled (TWAB = 0), then the thermal warning
recovery determines if the -3 dB output limit is removed when thermal warning is negative.
If TWRB = 0 and TWAB = 0, then when a thermal warning disappears the -3 dB output limit
is removed and the gain is added back to the system. If TWRB = 1 and TWAB = 0, then
when a thermal warning disappears the -3 dB output limit remains until TWRB is changed to
zero or the device is reset.
26/68